ND-210729C: Difference between revisions
(created ND-210729C page) |
(→Documentation: added C06 version of PD, marked the last PD document as belonging to the C03 version) |
||
Line 26: | Line 26: | ||
== Documentation == | == Documentation == | ||
PD- or PI-sheet | PD- or PI-sheet | ||
* Program Description [https://drive.google.com/open?id=0B2Sc5Qa5d_tLV21XYmtJRENPNUU ND-210729C.pdf] | * C03: Program Description [https://drive.google.com/open?id=0B2Sc5Qa5d_tLV21XYmtJRENPNUU ND-210729C.pdf] | ||
* C06: Program Description [https://drive.google.com/open?id=0B2Sc5Qa5d_tLNTA4M04ybFVtaEk ND-210729C.pdf] | |||
Manuals | Manuals | ||
* {{ND-doc|60.206.3 EN}} | * {{ND-doc|60.206.3 EN}} |
Revision as of 10:48, 15 September 2016
UNIQUE-II SIBAS for ND-100
Description
4th generation program for storing, modifying and retrieving data in SIBAS database systems.
This article is a stub. You can improve NDWiki by expanding it. |
Prerequisites
The following are required in order to use this product.
Hardware
Computer: ND-100, ND-100 CX or ND-110 CX
Floating format: 32 or 48 bit
Software
Operating system: SINTRAN III VS >= version I (for ND-100), SINTRAN III VSX >= version I (for ND-100 CX and ND-110 CX)
Other:
- 210166F SIBAS-II For ND-100 version F
or
- 211143A SIBAS/R, version A
- 210507B Software Keys
- 211005C UNIQUE Text System, version C
- 210721B BRF-LINKER, version B
- (210518C USER ENVIRONMENT, version C) (optional)
- 210079M NOTIS-WP, version M (may be replaced by PED)
- 210518C File: UE-PLIB-2B-C:BRF User Environment Library
Documentation
PD- or PI-sheet
- C03: Program Description ND-210729C.pdf
- C06: Program Description ND-210729C.pdf
Manuals
- Norsk Data Document ND–60.206.3 EN Dialogue-UNIQUE-II User Guide
- Norsk Data Document ND–60.206.3 NO Dialogue-UNIQUE-II User Guide
- Norsk Data Document ND–60.210.3 EN DIALOGUE - UNIQUE-II Application Development
- Norsk Data Document ND–60.210.3 NO DIALOGUE - UNIQUE-II Application Development
- Norsk Data Document ND–60.281.1 EN DIALOGUE-UNIQUE-II Programming Examples
Installation
Preparations
Prior to the installation, verify the following:
- That your installation fulfills the requirements on page 1.
- That the user areas specified on page 1 exists with the specified number of free pages and free files. If not, find a directory having enough space to hold the users. The installation program will try to allocate space whenever needed, but you may need to specify on which directory to create user areas.
- If (and where)
(DIALOG-SYS)SIBLIB2:BRF
and(USER-ENVIRONMENT)UE-PLIB-2B-C:BRF
are installed. If not installed on the default user area, the installation program will ask where to find these files.
Installation from floppy
- put the floppy disk into the machine.
- Log in to user area SYSTEM.
- Enter directory 210729C<rev>-XX-01 on the floppy disk.
- Run the INSTALL program on the floppy disk.
If using single-sided diskettes, replace the diskettes as instructed. The installation program will guide you trough the installation.
The following is an example on how to enter the directory and start the installation program.
@ENTER-DIRECTORY 210729C<rev>-XX-01D FLOPPY-DISC-1 0 @(210729C:FLOPPY-USER)INSTALL
You may install UNIQUE on any user area, but DIALOG-SYS is recommmended in the installation program.
After installing UNIQUE
After a succcessful installation of UNIQUE, you must update the file DUMP-REENTRANT:MODE with the following command:
@MODE (<load-user>)UNIQ-DUMP-S1-C:MODE (<load-user>)UNIQ-DUMP-S1-C:LIST
where <load-user> is the name of the user where the :PROG files are loaded.
Date
Date of release, production, revision.
Date: 1987.08.31
Media
Labels
Images
Images (made with dd) of 5.25 inch floppies.