Search results

Jump to navigation Jump to search

Page title matches

  • Document FluxEngine testing. === 2021 === ; 2021-02-05 : using the ... ; 2020-02-04 : doing some regression testing. I've updated FluxEngine ...
    35 KB (2,750 words) - 16:10, 5 February 2021
  • document Greaseweazle testing. === 2021 === ; 2021-02-05 : read a 5 ... No - needs more testing ...
    35 KB (3,867 words) - 16:23, 5 February 2021

Page text matches

  • manager at Norcontrol Horten, Tarald Frette, testing a NORD-42]] == Sources == Category:Norsk Data hardware ...
    862 bytes (128 words) - 16:18, 22 July 2016
  • anything, this will be a machine thats used for testing. ... smaller, modern and suitable for a testing system after going through it. ...
    2 KB (312 words) - 07:21, 20 February 2019
  • The program DISC-TEMA is intended to be a service and maintenance program which can be used for testing and verifying a disk or a disk system ...
    887 bytes (135 words) - 19:35, 20 May 2020
  • === Testing a Seagate ST31200N drive with SCSI-TV === I used SCSI-TV-B00 for testing a Seagate ST31200N drive. ...
    6 KB (805 words) - 20:37, 26 April 2023
  • Subpages: testing, The FluxEngine is a very cheap USB floppy disk interface ... with gw hw and fe sw, and it works, see testing subpage. ...
    6 KB (876 words) - 16:39, 5 February 2021
  • * Butterfly-110 ND Diagnostics : Test programs for testing hardware and file system (File System Investigator). == Sources and references == ...
    2 KB (231 words) - 06:58, 5 September 2024
  • Subpages: testing, == Hardware setup == You will need a computer with ... the floppies was written with). I'm testing keirf's Disk Utilities ...
    7 KB (1,021 words) - 15:12, 5 February 2021
  • This page documents testing of SINTRAN III on the machine ND-100/CX Compact (3392.1669). == Version == This machine has SINTRAN III - VSX / 500 ...
    5 KB (598 words) - 08:38, 4 August 2020
  • * Use it for testing of ND-100 cards. * Use it for imaging 5.25" floppies. * Connect it to internet via ethernet. ==Location== ...
    2 KB (315 words) - 19:55, 28 September 2016
  • This instruction is used for testing and simulating of data transfer ... % Do the testing here % Reset the interface to clear test mode ...
    8 KB (1,213 words) - 15:34, 14 January 2018
  • ; 2016-07-09 : more testing - try to load and run CONFIGURATIO-D00:TEST. ... ; 2016-07-09 : testing - I connected up the console again, and inserted ...
    11 KB (1,647 words) - 20:59, 6 September 2024
  • Document FluxEngine testing. === 2021 === ; 2021-02-05 : using the ... ; 2020-02-04 : doing some regression testing. I've updated FluxEngine ...
    35 KB (2,750 words) - 16:10, 5 February 2021
  • code of the CPU. It can be used for low level testing of the hardware. Whenever the MOPC is active it is communicating via the console connected ...
    4 KB (579 words) - 15:21, 14 January 2018
  • Testing the terminal ports: port 2 - RS-232 - doesn't work - terminal ... ; 2010-11-29 : Testing the fxed disk drive with DISC-TEMA (from ND ...
    15 KB (2,373 words) - 18:59, 5 September 2024
  • * Use it for testing of ND-100 cards * Use it for imaging 5.25" floppies * Connect it to internet via a serial to TCP-IP converter. ...
    5 KB (604 words) - 17:04, 19 September 2016
  • Subpages: SINTRAN III testing, == Hardware == Hardware in the machine ... ; 2011-10-21 : hard drive - to prepare for hard drive testing, I rigged ...
    15 KB (2,464 words) - 16:03, 22 October 2023
  • Written for field service engineers and personnel testing ND-500 CPUs ... wanting to write their own microrogram testing routines. ...
    24 KB (3,191 words) - 19:17, 4 February 2021
  • * Start testing SCSI2SD as an alternative to the physical disk. * New: Fix the keyboard of the Nokia Notis-terminal to make it usable again. ...
    8 KB (1,347 words) - 15:00, 25 September 2024
  • document Greaseweazle testing. === 2021 === ; 2021-02-05 : read a 5 ... No - needs more testing ...
    35 KB (3,867 words) - 16:23, 5 February 2021
  • [[Image:CERN-PHOTO-7403017.jpg |300px | thumb | Testing electronics at CERN with a NORD-10. ]] There have been several (at least two) ways of ...
    14 KB (1,884 words) - 16:33, 3 November 2024

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)