ND-211068A
Operator Environment.
Description
New modules for computer operation, tied together with a menu system.
This article is a stub. You can improve NDWiki by expanding it. |
Prerequisites
The following are required in order to use this product.
Hardware
Computer: ND-100.
Software
Operating system: SINTRAN III >= version K
Other:
Documentation
PD- or PI-sheet
- Program Description ND-211068A.pdf
Manuals
- Norsk Data Document ND–30.061.1 EN [[Documentation list#Unknown|]]
- Norsk Data Document ND–99.040.1 EN OPERATOR ENVIRONMENT QUICK REFERENCE CARD
Installation
The system may be delivered on:
- 1.2 Mbyte, 8 inch or 5 1/4 inch double-sided diskettes
or
- 0.3 Mbyte, 8 inch single-sided diskettes.
You must use the same kind of diskettes throughout the installation procedure. You may (1) install the OE Basic Modules with desired language or (2) add desired language to OE. If you add desired language to OE, remember that you have to add up the required user space to user ND-OPERATIONS. Check with the column "Add.lang." under prerequisites on page 1. The installation procedure is fully interactive, which means that once started, it will continuously check the operation. It will inform the operator if any error occurs and tell how to proceed. The operator is also asked some questions about the specific configuration. By typing '?' and ENTER some additional information is provided.
You will be asked about which OE modules you want to install.
How to start the installation
- Remember prerequisites, see page 1.
- The installation must be run from SINTRAN
- Log in as SINTRAN user name SYSTEM.
- Insert the diskette containing the directory name 211068A<rev>-<lang>-01 into the diskette station. NOTE! <lang> means language suffix ('EN' or 'NO')
- Execute these commands (operator input is underlined and parameters are enclosed in angle brackets):
@ENTER-DIRECTORY,211068A-<lang>-01 DEVICE NAME: FLOPPY-DISC-<drive no.> DEVICE UNIT: <floppy unit> @(211068A:FLOPPY-USER)INSTAL-OE
The installation procedure has now started. It is self-explanatory.
- If you install at least one of the products
- User Area Manager
- Backup and Restore with TRUE
- Configuration Dictionary
- Status Program
- File Manager
You must remember to update your HENT-MODE file under user SYSTEM with
@MODE (ND-OPERATIONS)Oe-LOAD:MODE,,
- If the Configuration Dictionary is installed
Insert (into) the LOAD-MODE file under user SYSTEM behind the point where you start User Environment:
@(ND-OPERATIONS)OE-FUNC start-server
This command checks that the current time is later than stop time, if not, it sets completion code to 34747B and LOAD-MODE must take appropriate actions to handle it.
- If the Configuration Dictionary is installed
insert (into) the STOP-MODE file before the point where you stop User Environment:
@(ND-OPERATIONS)OE-FUNC stop-server
This command stores the stop time.
- For extended NOTIS support, NOTIS-DS-C and NOTIS-ID-B are required.
- Operator must have appropriate access to the NOTIS-DS archive
MAILING-LIST/OUTTRAY/(SYSTEM)MAILBOX
to be able to update the mailing list
- Anyone can use the OPERATOR ENVIRONMENT menu system by connecting the menu system to a User Profile in USER ENVIRONMENT (UE-PMAN). Example of a user profile for a user with maximum authorization:
User name : JOHN BROWN Password : Standard task : UE-MENU Language : ENGLISH User level : ADVANCED User groups : 0 Authorization : SUPERVISOR Sintran: YES Letters: 0 Main user area : ND-OPERATIONS Alternative areas : 1 Enter: SYSTEM with correct password Menu system : (ND-OPERATIONS)OEM-MENUE
Main user area does not need to be ND-OPERATIONS.
Any authorization codes for SINTRAN, other than SYSTEM as alternative area, will decrease the number of functions for a user of OPERATOR ENVIRONMENT.
Date
Date of release, production, revision.
Date: 1987.04.29
Media
Labels
Images
Images (made with dd) of 5.25 inch floppies.
- 211068A00-XX-01D.image.gz
- 211068A00-XX-02D.image.gz
- 211068A00-EN-01D.image.gz
- 211068A00-EN-02D.image.gz
or all in a zip file