163 I/O output and clock, is a card that is used in the NORD-1 CPU.
Introduction
The card is made in the standard NORD-1 card format.
CPU model | Crate position |
---|---|
29 | D20 |
35 | D20 |
The logic diagram is documented in drawing 2A63.[1]
Switches and indicators
There seems to be a way to select between 100 Hz, 50 Hz, 25 Hz and 12.5 Hz interrupt from the real time clock.
BOM
This list contains the logic circuits used, passive components are not listed.
- 3 x 7400
- 1 x 7401
- 2 x 7402
- 6 x 7404
- 1 x 7413
- 2 x 7420
- 1 x 7453
- 4 x 7474
Reference
- ↑ HARDWARE MANUAL NORD 1
- Hardware in NORD-1 Serial 47