IOX
IOX | |
---|---|
Description | Exchange information between I/O system and A register. |
Format | IOX <device register address> |
Code | 164 0008 |
Affected | See description |
Type | See description |
Architecture | ND-100, ND-110 |
IOX is an assembly instruction used for programmed IO, and it transfers data between a device I/O register and the CPU's A register.
IOX (the Input/Output Instruction) is a privileged instruction in normal cases, but if there is no OS running and the paging system is turned off then IOX is an unprivileged instruction. IOX and IOXT are the only instructions used to communicate with external interfaces.
Direction of transfer
The actual transfer direction of the IOX and IOXT instructions is decoded from the device-register address, based on the following convention: the transfer direction is input (from device to CPU) if the device-register address is even.
This means that all I/O device registers which need to be loaded from the CPU A register are assigned and odd device register address. Similarly I/O device input registers are assigned even addresses.
Device register address
Register addresses can hold data, command or status information for a device.
Bit 0-10 of the instruction code sets the direction and IO address:
- Bit 0 gives the direction of transfer:
- If bit 0 is zero then IOX reads the value from the IO register into register A
- If bit 0 is one then IOX writes the contents of register A to the IO register
- Bit 3-9 is the selected device
- Bit 0-2 is the selected register within selected device
- Bit 10 is the type of interface:
- If bit 10 is zero then it is a Standard ND interface
- If bit 10 is one then it is a Customer designed interface
An external device may require more than one register address, for example a magnetic tape unit may need several register addresses; these should be given successive device-register addresses (remembering to use odd addresses for input and even addresses for output).
Note
- Addressing of a non existing device results in a IOX error.
- The number of external devices that can be controlled by the CPU depends on the configuration of the devices.
Example
To give an instruction to a device
LDA <device command code> IOX <device register address>
The lsb of IOX will be 1. The A register contents are output to the device addressed within the IOX opcode.
To check the status of a device
IOX <device register address>
The lsb of IOX will be 0. The status code of the device addressed by the IOX opcode will be loaded into the A register.
Transfer data
IOX <device register address>
Data from the device addressed by the IOX instruction is read into the A register if the lsb of IOX is 0. If the lsb of IOX is 1, the A register contents are output to the device.
Se also
- IOXT instruction
References
- Norsk Data Document ND–06.015.02 ND-100 FUNCTIONAL DESCRIPTION (Programmed I/O, chapter 6.3, page 170-172)
- Norsk Data Document ND–06.026.1 ND-110 Functional Description (The Input/Output Instructions IOX and IOXT, page 141)
- Norsk Data Document ND–06.029.1 ND-110 Instruction Set (Input/Output Instructions, page 121-122)