ND-110 Satellite 9883.21005
A ND-110 Satellite model T9 machine that I got from Gandalf.
Subpages: SINTRAN III install, SINTRAN III start errors, Test programs run,
Hardware
Hardware in the machine is described in this section.
Cards
- empty
- 3094 ETHERNET IF. II - print: E, eco: G
- 3095 ND110 CPU&MM 4BB, print: , eco: J
- 3201 SCSI/FLOPPY, print: C, eco: J
- 3042 N0100 2MBY RAM, print: B, eco: D
- empty
- 3013 N0100 8 TERM IF, print: M, eco: N
Devices
- floppy drive : 1.2 Megabytes, 5.25 inch, ND 103161, another label says ND 187-3104.
- tape streamer : Tandberg TDC 3640, ND 229-0898, SCSI.-id: 1.
- Hard drive : Quantum ProDrive LPS 540 S, a 3.5 inch slimline SCSI drive, 540 Megabytes. SCSI-id: 0.
Power Supply
- Wiener DN 03, 390 W
Connectors
Labels
On the inside of the front door
- printed label at the top
NORSK DATA FLOPPY: 187-3044 STREAMER: 229-898
- handwritten label near the bottom
ORD: 20.6578 E CPU: 9883.21005
On the front of the cabinet (behind the front door)
- printed label above tape streamer / floppy drive
LOGNR 9053
History
- 2016-07-12
- SINTRAN III, M05 install - completed the Sintran install, see the subpage. Unfortunately, I still get errors when I try to start Sintran.
- floppy drive - I ran the FLOPPY-STREAMER test program from my ND-100 Test Programs floppy, but it reports the floppy controller as "UNKNOWN CONTROLLER" - perhaps I need a newer program.
- floppy drive - the borrowed floppy drive didn't work at all, so I put the original one back in.
- floppy drive - I borrowed the floppy drive from my ND-100/CX Compact, I'm going to test if it works any better than the original one.
- 2016-07-11
- floppy drive - it is ND 187-3104 (another label says ND 103161), which is a Toshiba FDD 5862A0K 03 REV. A.
- hard drive - I changed SCSI id to 0 (zero) by removing the A2 and A1 jumpers. According to SINTRAN III release L release notes, SCSI id 0 is needed for SINTRAN III to boot from the drive.
- tape streamer - checking out the streamer. I took out the media tray again; the streamer is ND 229-0898, a SCSI, Tandberg TDC 3640 with 64 K buffer option. It is set fro SCSI-id 1.
- SINTRAN III, M05 install - after changing SCSI-id to 0 (zero) on the hard drive, I managed one complete install, but SINTRAN wouldn't start. after that, the floppy drive started acting up.
- 2016-07-10
- mounting a hard drive. This evening I took out the media tray (it sits with two screws, after that it slides out) it looks like it is connected via the standard A, B and C connectors of a ND-100 bus. I used a "Drevramme 3.5 inch to 5.25 inch - intern" (100457) that I had to mount the 3.5 inch drive to the 5.25 inch holes in the media tray. Next I connected up SCSI (standard 50 pin IDC) and power cables (4-pin molex "hard drive" male plug on both ends). I put the media tray back into the machine, and secured it with the two screws. The hard drive is a Quantum ProDrive LPS 540 S, a 3.5 inch slimline drive with 540 megabyte capacity. It is set for SCSI-id 6.
- 2016-07-09
- more testing - try to load and run CONFIGURATIO-D00:TEST.
TPE>load config CONFIGURATION - Version: D00 - 1986-12-08 TPE>
Next I do "run" and the program says
CPU type: ND-110 or ND-110/CX
Floating format: 48 bits
Memory Management: MMS-2 included on CPU card
Cache: Yes
ALD Register: 21560B
Total memory size: 2.512 Mbytes
Devices, the machine has
real time clock 1 10 13
Terminal interfaces 1, 5, 6, 7 ,8, 9, 10, 11, 12
(logical device number are 1, 44, 45, 46, 47, 60, 61, 62, 63)
ECCR
Ethernet controller 1 140360 140363 (logical device number 2240)
SCSI Interface 1 144300 144377 (logical device number 2202)
and no errors. Nice.
I loaded CACHE-110
CACHE-110 - Version: A00 - 1986-10-15 This is a ND-110 CPU (One instruction cache). TPE>
and I ran it (All-tests) there are 8 tests. It takes a while to run through all tests, but they finished without errors. I Loaded MEMORY
MEMORY - Version: D00 - 1986-10-30 THIS IS A NORD-100 WITH 1280K WORDS(16-BIT) MEMORY (DEC.) TPE>
did "run" which ran all tests. It also said
(HOLES IN DEFINED TEST AREA) AREA TESTED: 0.11-35.15 READ TEST ON PROGRAM PART === END OF TEST === ADRESSES IN ADRESSES === END OF TEST === WRITE/READ TEST (7 PATTERNS) === END OF TEST === RAPIDLY CHANGING ADDRESS BITS === END OF TEST === PARITY ERROR DETECTION === END OF TEST === WALK TEST (34 PATTERNS) === END OF TEST === === THE TESTS ARE NOW LOOPING === =ESCAPE== TPE>
that's it.
- 2016-07-09
- testing - I connected up the console again, and inserted the floppy labeled "210523E00-XX-01D Test Programs for ND-100 release date 870715 870108". On the console I wrote
MACL 1560&
(the last one without enter), and few seconds later the console prints
TPE Monitor, ND-100 / ND-110 - Version: A02 - 1986-10-30 The command HELP gives you the full list of available commands TPE>
available commands are
MODE <input file name> <output> DATCL DELETE-MACROS DUMP-PRINTER-BUFFER (<from> <to>) EXIT EXPLAIN-COMMAND <command> HELP <command> LIST-FILES <file name> LIST-MACROS <macro name> LOAD-PROGRAM <file name> DEFINE-MACRO <name> <body> MONITOR-HELP <command> OPCOM PRINT-NOTE <note-number> PROGRAM-HELP <command> PROGRAM-STATUS SET-CONSOLE-DEVICE-NUMBER <logical or hardware number> SET-PRINTER-DEVICE-NUMBER <logical or hardware number> SET-PRINTER-MODE <mode> (<buffer size>) SET-TERMINAL-TYPE <type> TERMINAL-MODE <full page stop> UPDAT <minute> <hour> <day> <month> <year>
let me check the panel clock
TPE>datctl 1985.03.09 04:55:07
update it
TPE>updat 49 16 09 07 2016
check
TPE>datcl 2016.07.09 16:49:43
that worked.
- 2016-07-02
- testing - I connected power, used the Nokia VDU 301 S as a console (I just soldered up a new current loop cable). When I turn the keyswitch to on, the machine starts up and "STOP" and "START" lights up on the front panel. The console prints "#" - everything looks ok.
- 2016-06-30
- the machine got delivered by Gandalf and friend, all the way from Umeå, Sweden. A Nokia VDU 301 S terminal also came in the same delivery.
- 2016-06-28
- Gandalf had set up a rescue trip to Norway (to save a NORD-1), and graciously donated a ND-110 Satellite to me. The machine didn't have a hard drive, but use a SCSI hard drive. A friend in Tromsø made floppy images for SINTRAN III, M-release (M05) available to me.