JAF
Jump to navigation
Jump to search
| JAF | |
|---|---|
| Description | Jump if A filled (not zero) |
| Format | JAF <disp.> |
| Code | 131 4008 |
| Affected | If A<>0 (P):=(P)+Δ |
| Type | User |
| Architecture | ND-100, ND-110 |
JAF is an assembly instruction. If the A register is not zero, it jump the program execution to the address of the program counter (P register) plus the value of displacement, that can be between -128 to 127. Else it continue the program execution at (P) + 1.
References
- Norsk Data Document ND–06.014.02 ND-100 REFERENCE MANUAL Page 139
- Norsk Data Document ND–06.029.01 ND-110 Instruction Set Page 79