ND-211005C
UNIQUE Text System
Description
Language-dependent part of UNIQUE Products.
This article is a stub. You can improve NDWiki by expanding it. |
Prerequisites
The following are required in order to use this product.
Hardware
Software
Operating system: SINTRAN III VS / VSX >= version I (for ND-100) or SINTRAN III VSX/500 >= version I (for ND-500).
Documentation
PD- or PI-sheet
- Program Description ND-211005C.pdf
Manuals
- Norsk Data Document ND–60.206.3 EN Dialogue-UNIQUE-II User Guide
- Norsk Data Document ND–60.206.3 NO Dialogue-UNIQUE-II User Guide
- Norsk Data Document ND–60.210.3 EN DIALOGUE - UNIQUE-II Application Development
- Norsk Data Document ND–60.210.3 NO DIALOGUE - UNIQUE-II Application Development
- Norsk Data Document ND–60.281.1 EN DIALOGUE-UNIQUE-II Programming Examples
Installation
Introduction
All messages / texts used by Unique products come from the language dependent UNIQUE Text System files under user DIALOG-SYS.
The Text System must be properly installed before any UNIQUE products may be run.
Some language dependent examples are included on the diskette, but to install these you must run the installation program for UNIQUE or XTRA and select the option INSTALL EXAMPLES.
NOTE: There is no example of 'Exit to editor' (NOTIS-WP/Wide-column), but it is possible to include this if you use SIBAS/R. In the DIALOGUE - UNIQUE Programming Examples Manual there are examples on how to do this.
Installation
The installation is done by a program provided on the floppy.
The following is an example of the installation of UNIQUE Text System (user input underlined).
Log in as user SYSTEM:
@ENTER-DIRECTORY 211005C<rev>-<lang>-01 F-D-1 0 @(211005C:FLOPPY-USER)TEXT-SYS-IN
This program will copy all the files from the floppy to the user areas DIALOG-SYS, ND-OPERATIONS and SYSTEM. The user area will be created or expanded if necessary. If using single-sided diskettes, replace the diskettes as instructed. The installation program will guide you through the installation.
Error messages
If the Text System has been incorrectly installed or is out of date, the following error messages may appear when running a UNIQUE product:
'Can not open message file (DIALOG-SYS)UNIQUE-<lang>-C:UTXT'
This will result if you do not have read and common (RC) access to the file or the file does not exist. Check that the language file you requested exists on user DIALOG-SYS with public read and common (RC) access. Also check if the program you tried to run requires a newer version of the Text System. Contact your distributor for the latest version of the Text System.
Date
Date of release, production, revision.
Date: 1988.02.05
Media
Labels
Images
Images (made with dd) of 5.25 inch floppies.