ND-1xx Instructions Sorted Numerically
Jump to navigation
Jump to search
See also: ND-1xx Instructions
Instruction Set
NORD-10/ND-100/ND-120 instructions are all exactly 16 bits (1 word) long. Addressing mode, displacement, source register, destination register are, when applicable, encoded inside the 16-bit instruction word itself.
Opcode | Instruction |
---|---|
000000 | STZ |
004000 | STA |
010000 | STT |
014000 | STX |
020000 | STD |
024000 | LDD |
030000 | STF |
034000 | LDF |
040000 | MIN |
044000 | LDA |
050000 | LDT |
054000 | LDX |
060000 | ADD |
064000 | SUB |
070000 | AND |
074000 | ORA |
100000 | FAD |
104000 | FSB |
110000 | FMU |
114000 | FDV |
120000 | MPY |
124000 | JMP |
130000 | JAP |
130400 | JAN |
131000 | JAZ |
131400 | JAF |
132000 | JPC |
132400 | JNC |
133000 | JXZ |
133400 | JXN |
134000 | JPL |
140000 | SKP |
140120 | ADDD |
140121 | SUBD |
140122 | COMD |
140123 | TSET |
140124 | PACK |
140125 | UNPACK |
140126 | SHDE |
140127 | RDUS |
140130 | BFILL |
140131 | MOVB |
140132 | MOVBF |
140133 | VERSN |
140134 | INIT |
140135 | ENTR |
140136 | LEAVE |
140137 | ELEAV |
140300 | SETPT |
140301 | CLEPT |
140302 | CLNREENT |
140303 | CHREENTPAGES |
140304 | CLEPU |
140500 | WGLOB |
140501 | RGLOB |
140502 | INSPL |
140503 | REMPL |
140504 | CNREK |
140505 | CLPT |
140506 | ENPT |
140507 | REPT |
140510 | LBIT |
140511 | LBITP |
140512 | SBIT |
140513 | SBITP |
140514 | LBYTP |
140515 | SBYTP |
140516 | TSETP |
140517 | RDUSP |
140600 | EXR |
140700 | LASB |
140701 | SASB |
140702 | LACB |
140703 | SACB |
140704 | LXSB |
140705 | LXCB |
140706 | SZSB |
140707 | SZCB |
141200 | RMPY |
141600 | RDIV |
142200 | LBYT |
142600 | SBYT |
142700 | GECO |
143100 | MOVEW |
143200 | MIX3 |
143300 | LDATX |
143301 | LDXTX |
143302 | LDDTX |
143303 | LDBTX |
143304 | STATX |
143305 | STZTX |
143306 | STDTX |
143500 | LWCS |
143600 | IDENT |
144000 | SWAP |
144400 | RAND |
145000 | REXO |
145400 | RORA |
146000 | RADD |
146100 | COPY |
146100 | RCLR |
146142 | EXIT |
146300 | RDCR |
146400 | RINC |
146600 | RSUB |
150000 | TRA |
150100 | TRR |
150200 | MCL |
150300 | MST |
150400 | OPCOM |
150401 | IOF |
150402 | ION |
150404 | POP |
150405 | PIOF |
150406 | SEX |
150407 | REX |
150410 | PON |
150412 | PION |
150415 | IOXT |
150416 | EXAM |
150417 | DEPO |
151000 | WAIT |
151400 | NLZ |
152000 | DNZ |
152402 | SRB |
152600 | LRB |
153000 | MON |
153400 | IRW |
153600 | IRR |
154000 | SHT |
154200 | SHD |
154400 | SHA |
154600 | SAD |
164000 | IOX |
170000 | SAB |
170400 | SAA |
171000 | SAT |
171400 | SAX |
172000 | AAB |
172400 | AAA |
173000 | AAT |
173400 | AAX |
174000 | BSET |
175000 | BSKP |
176000 | BSTC |
176200 | BSTA |
176400 | BLDC |
176600 | BLDA |
177000 | BANC |
177200 | BAND |
177400 | BORC |
177600 | BORA |
Note that GECO is an undocumented instruction. The undocumented NORD-1 instruction IOT (not listed) is also partly supported by NORD-10 and ND-100 CPUs: IOT SKA (opcode 161000) is the equvialent of MONitor calls for the range 0-127 (MON 0 .. MON 177).
Sources
- Norsk Data Document ND–06.014 ND-100 REFERENCE MANUAL (ND-06.014.02 rev A)
- Norsk Data Document ND–06.029 ND-110 Instruction Set (ND-06.029.01 rev A)
- Norsk Data Document ND–99.005 ND-100 INSTANT INSTRUCTION CODES (ND-99.005.02 12/84)