ND-06.015: Difference between revisions
Jump to navigation
Jump to search
(More data...) |
(More data...) |
||
Line 366: | Line 366: | ||
D.14.7 Transmission Clock Indicator (Yellow LED) | D.14.7 Transmission Clock Indicator (Yellow LED) | ||
D.15 Switch and Indicators on the N10 Bus Adapter (3024) | D.15 Switch and Indicators on the N10 Bus Adapter (3024) | ||
D.15.1 | D.15.1 External Bus Number Selection (Thumbwheel) | ||
D.15.2 | D.15.2 Block Switch Setting (SW 1) and Reading (LED 3) | ||
D.15.3 | D.15.3 CIO Switch Setting (SW 3) and Reading (LED 1) | ||
D.15.4 | D.15.4 The Fast DMA Setting (SW 4) and Reading (LED 2) | ||
D.16 Switches and Indicators on the GPIB Controller (3026) | D.16 Switches and Indicators on the GPIB Controller (3026) | ||
D.16.1 Device Number Selection (Thumbwheel TH1) | D.16.1 Device Number Selection (Thumbwheel TH1) | ||
D.16.2 | D.16.2 System Controller Selection | ||
D.16.3 | D.16.3 The LED Indicators | ||
D.17 Switch and Indicators on the Floppy Disk Controller for DMA (3027) | D.17 Switch and Indicators on the Floppy Disk Controller for DMA (3027) | ||
D.18 Switches and Indicators on the Bus Expander (BEX) (3028) | D.18 Switches and Indicators on the Bus Expander (BEX) (3028) | ||
D.18.1 | D.18.1 Limit Switches | ||
D.18.2 | D.18.2 The Display | ||
D.18.3 | D.18.3 BEX Numbers | ||
D.18.4 | D.18.4 The Vital Switch and Indicators | ||
D.18.5 | D.18.5 The Allow Switch | ||
D.19 Switches and Indicators on the N100 Bus Controller (3031) | D.19 Switches and Indicators on the N100 Bus Controller (3031) | ||
D.19.1 | D.19.1 Limit Switches | ||
D.19.2 | D.19.2 Device Numbers | ||
D.19.3 | D.19.3 Limit Display | ||
D.19.4 | D.19.4 Interleave | ||
D.19.5 | D.19.5 Timeout Selector | ||
D.20 Switches and Indicators on the Memory Port-MPM4 (3032) | D.20 Switches and Indicators on the Memory Port-MPM4 (3032) | ||
D.20.1 | D.20.1 Limit Switches | ||
D.20.2 | D.20.2 Interleave | ||
D.20.3 | D.20.3 Interleave Bank Selector | ||
D.20.4 | D.20.4 Refresh Timeout | ||
D.20.5 | D.20.5 ADOK | ||
D.20.6 | D.20.6 Grant | ||
D.21 Switches on the CPU Module, Including the CX Option (3033) | D.21 Switches on the CPU Module, Including the CX Option (3033) | ||
D.21.1 | D.21.1 ALD - Automatic Load Descriptor | ||
D.21.2 | D.21.2 Console: Speed Settings for Console Terminal | ||
D.21.3 | D.21.3 The Indicators (The Red and Green LEDs) | ||
D.22 Switches and Indicators on the 256 K Memory Module (3034) | D.22 Switches and Indicators on the 256 K Memory Module (3034) | ||
D.22.1 | D.22.1 Memory Address Range and Upper Limit reading | ||
D.22.2 | D.22.2 Setting the ENAB/DISAB Switch | ||
D.22.3 | D.22.3 The LED Indicators | ||
D.23 Switches and Indicators on | D.23 Switches and Indicators on thTe 64 K Memory Module (3036) | ||
D.23.1 | D.23.1 Memory Address Range and Upper Limit reading | ||
D.23.2 | D.23.2 Setting the ENAB/DISAB Switch | ||
D.23.3 | D.23.3 The LED Indicators | ||
D.24 Switches and Indicators on the 8" Disk Controller (3038) | D.24 Switches and Indicators on the 8" Disk Controller (3038) | ||
D.24.1 Device Number Selection (Thumbwheel) | D.24.1 Device Number Selection (Thumbwheel) | ||
D.24.2 | D.24.2 The LED Indicators | ||
D.25 Switches and Indicators on the N100 Bus Controller (3039) | D.25 Switches and Indicators on the N100 Bus Controller (3039) | ||
D.25.1 | D.25.1 Memory Boundaries Setting and Reading | ||
D.25.2 Device Number Selection (Thumbwheel) and Extended Device Number Diode Reading | D.25.2 Device Number Selection (Thumbwheel) and Extended Device Number Diode Reading | ||
D.25.3 | D.25.3 Interleave Setting (Thumbwheel) | ||
D.25.4 | D.25.4 Timeout Setting and Reading | ||
D.25.5 | D.25.5 The Address OK Indicator (yellow LED) | ||
D.26 Switches and Indicators on the 5 1/4" Disk Controller (3041) | D.26 Switches and Indicators on the 5 1/4" Disk Controller (3041) | ||
D.26.1 | D.26.1 Device Number Selection (Thumbwheel) | ||
D.26.2 | D.26.2 The LED Indicators | ||
D.27 Switches and Indicators on the 15MHz ECC Disk Controller (3043 and 3044) | D.27 Switches and Indicators on the 15MHz ECC Disk Controller (3043 and 3044) | ||
D.27.1 SMD Control | D.27.1 SMD Control | ||
Line 426: | Line 426: | ||
D.27.2.2 Indicators, LED 1-LED 3 | D.27.2.2 Indicators, LED 1-LED 3 | ||
D.28 Switches and Indicators on the PIOC (3101) | D.28 Switches and Indicators on the PIOC (3101) | ||
D.28.1 | D.28.1 PIOC Number Setting (Switch 12J) | ||
D.28.2 | D.28.2 Bank Number Selection (Switches 7J and 8J) | ||
D.28.3 | D.28.3 Lowest Address Selection/Reading (Switches 7J and 9J) | ||
D.28.4 | D.28.4 The LED Indicators | ||
D.29 Switch and Indicator on the Memory Management II (3104) | D.29 Switch and Indicator on the Memory Management II (3104) | ||
D.29.1 | D.29.1 Cache Memory Enable/Disable Switch and Indicator | ||
D.30 Switches on the 8-Telex Interface (3105) | D.30 Switches on the 8-Telex Interface (3105) | ||
D.30.1 | D.30.1 Extended Address Selection (TH1 and TH2) | ||
D.30.2 | D.30.2 Terminal Group Selection (TH2 and TH4) | ||
D.30.3 | D.30.3 Baud Rate Selection (TH1 and TH2) | ||
D.31 Switches on the Floppy and Streamer Controller (3106) | D.31 Switches on the Floppy and Streamer Controller (3106) | ||
D.31.1 | D.31.1 Device Number Selection (Thumbwheel) | ||
D.31.2 | D.31.2 Error Codes Display | ||
D.32 Switches on the 8-Terminal Interface (3107) | D.32 Switches on the 8-Terminal Interface (3107) | ||
D.32.1 | D.32.1 Extended Address selection (TH1 and TH2) | ||
D.32.2 | D.32.2 Terminal Group Selection (TH2 and TH4) | ||
D.32.3 | D.32.3 Baud Rate Selection (TH1 and TH2) | ||
D.32.4 | D.32.4 Current Loop/RS 232 Selection | ||
D.33 Switches and Indicators on the PIOC Expanded (3108) | D.33 Switches and Indicators on the PIOC Expanded (3108) | ||
D.33.1 | D.33.1 PIOC Number Setting (Switch 12J) | ||
D.33.2 | D.33.2 Bank Number Selection (Switches 7J and 9J) | ||
D.33.2.1 | D.33.2.1 Bank Number Selection on PIOC/64 | ||
D.33.2.2 | D.33.2.2 Bank Number Selection on PIOC/256 | ||
D.33.3 | D.33.3 Lowest Address Selection/Reading (Switches 7J and 9J) | ||
D.33.4 | D.33.4 The LED Indicators | ||
D.34 Switches on the 8-Terminal Interface with Buffer (3111) | D.34 Switches on the 8-Terminal Interface with Buffer (3111) | ||
D.34.1 | D.34.1 Extended Address Selection (TH1 and TH2) | ||
D.34.2 | D.34.2 Terminal Group Selection (TH2 and TH4) | ||
D.34.3 | D.34.3 Baud Rate Selection (TH5 and TH6) | ||
D.34.4 | D.34.4 Current Loop/RS 232 Selection | ||
D.35 Switches on the Plotter/Printer Interface (3114) | D.35 Switches on the Plotter/Printer Interface (3114) | ||
D.35.1 | D.35.1 PCB Function Selection (DIP Switch in Pos. 13A) | ||
D.35.2 | D.35.2 Device Number Selection (Thumbwheel) | ||
E Microprogram-Panel Processor Communication | E Microprogram-Panel Processor Communication | ||
E.1 Information to Panel | E.1 Information to Panel Processor | ||
E.2 Panel Interrupt | E.2 Panel Interrupt | ||
E.3 Panel Status | E.3 Panel Status |
Revision as of 11:33, 6 November 2008
ND-06.015 ND-100 FUNCTIONAL DESCRIPTION
Description of the main building blocks of the ND-100 and their functions from a hardware point of view. Written for technical and maintenance personnel.
The manual contains a lot of technical information, from signals on the ND-100 bus to programming instructions fore some IO cards.
340 Pages.
Table of contents
Appendixes
Versions
- ND-06.015.01 Original printing 08/1980
- ND-06.015.02 Second version 04/1985
Known copies
A pdf copy is located on the Bitsavers website.
Related manuals
- Norsk Data Document ND–06.014 ND-100 REFERENCE MANUAL
- Norsk Data Document ND–06.016 ND-100 INPUT/OUTPUT SYSTEM
- Norsk Data Document ND–06.018 ND-100 MICROPROGRAMMING
Reference
Norsk Data Document ND–06.015 ND-100 FUNCTIONAL DESCRIPTION (ND-06.015.02 1985)