Test programs for ND-100/110.

Description

Test programs for ND-100/ ND-110 CPU's, ND-100 type interfaces and peripherals.

Prerequisites

Computer
ND100/110
Type
All
floating format
All
Operating system version
stand alone programs or SINTRAN III VSE/ VSX

Documentation

PD- or PI-sheet

Installation

Loading procedure - stand alone

The machine must be in STOP. Press MASTER CLEAR and type 1560& on console.

If autoload is not disabled (see description of FLOPPY-MON-H), TPE-MONITOR will start up and give the prompt:

TPE>

Manual loading:

FLOPPY-MON-H01
*LOAD TPE-MON-100

When TPE-MONITOR is started, use the command LOAD-PROGRAM to load the desired program:

TPE>LOAD-PROGRAM <program name>

or just:

TPE><program name>

The program is loaded if no error messages appear.

To list the programs available on diskette, use the command LIST-FILES:

TPE>LIST-FILES <file-name>

Online installation

The TPE-MONITOR can execute under SINTRAN in different modes.

Date

Date of release, production, revision.

Date: 1987.10.07

Media

Labels

Images

Images (made with dd) of 5.25 inch floppies.

  • 210523F01-XX-01D