MOVB: Difference between revisions
(MOVB instruction) |
(Typo fix) |
||
Line 8: | Line 8: | ||
}} | }} | ||
'''MOVB''' is an assembly instruction. A block of bytes | '''MOVB''' is an assembly instruction. A block of bytes is copied from the location specified for the source operand to the location specified for the destination operand. Overlap is taken care of. | ||
The source operand is defined by the [[A register|A]] and [[D register|D registers]]. The destination operand is defined by the [[X register|X]] and [[T register|T registers]]. | The source operand is defined by the [[A register|A]] and [[D register|D registers]]. The destination operand is defined by the [[X register|X]] and [[T register|T registers]]. | ||
Line 14: | Line 14: | ||
See [[BFILL]] for an explanation of how the operands are defined. Source: A and D registers. Destination: X and T registers. | See [[BFILL]] for an explanation of how the operands are defined. Source: A and D registers. Destination: X and T registers. | ||
The number of bytes copied is the shortest field | The number of bytes copied is the shortest field length value of the two operands. | ||
After execution both operands point to the end of the respective source- and destination fields (after the last byte copied). Bits 0-11 (field length) of the D register equals zero and bits 0-11 of the T register contain the number of bytes moved. | After execution both operands point to the end of the respective source- and destination fields (after the last byte copied). Bits 0-11 (field length) of the D register equals zero and bits 0-11 of the T register contain the number of bytes moved. |
Latest revision as of 13:56, 26 July 2010
MOVB | |
---|---|
Description | Move bytes |
Format | MOVB |
Code | 140 1318 |
Affected | P,A,D,X,T, memory region defined by X,T |
Type | User |
Architecture | ND-100, ND-110 |
MOVB is an assembly instruction. A block of bytes is copied from the location specified for the source operand to the location specified for the destination operand. Overlap is taken care of.
The source operand is defined by the A and D registers. The destination operand is defined by the X and T registers.
See BFILL for an explanation of how the operands are defined. Source: A and D registers. Destination: X and T registers.
The number of bytes copied is the shortest field length value of the two operands.
After execution both operands point to the end of the respective source- and destination fields (after the last byte copied). Bits 0-11 (field length) of the D register equals zero and bits 0-11 of the T register contain the number of bytes moved.
Bits 12-13 of the T register and bit 12 of the D register are used during execution, and are left cleared. Bit 13 must be zero before execution, it is used as an interrupt mark.
The P register is incremented by two when this instruction is finished, i.e. any instruction directly following MOVB will not be executed.
References
- Norsk Data Document ND–06.014.02 ND-100 REFERENCE MANUAL Pages 3-27,3-28
- Norsk Data Document ND–06.029.01 ND-110 Instruction Set Pages 92-93
The older document is more accurate and detailed for this instruction.