The '''NORD-50 monitor''' is a subsystem in the [[SINTRAN]] operating system, supervising execution of NORD-50 programs.<ref name="ND-10-OG">{{Weblink|http://www.sintran.com/sintran/library/libhw/libhw.html|30.001.01A NORD-10/NORD-50 Operator's Guide, Chapter 4.4}}</ref> | The '''NORD-50 monitor''' is a subsystem in the [[SINTRAN]] operating system, supervising execution of [[NORD-50]] programs.<ref name="ND-10-OG">{{Weblink|http://www.sintran.com/sintran/library/libhw/libhw.html|30.001.01A NORD-10/NORD-50 Operator's Guide, Chapter 4.4}}</ref> | ||
To use the monitor, it must have been loaded into SINTRAN as an [[RT program]]. The monitor is then started under SINTRAN by typing | To use the monitor, it must have been loaded into SINTRAN as an [[RT program]]. The monitor is then started under SINTRAN by typing |
Latest revision as of 21:22, 19 April 2014
The NORD-50 monitor is a subsystem in the SINTRAN operating system, supervising execution of NORD-50 programs.[1]
To use the monitor, it must have been loaded into SINTRAN as an RT program. The monitor is then started under SINTRAN by typing
@N-50
on a terminal connected to the system.
Main tasks[1] of the monitor are:
- loading programs from files into NORD-50 memory. These programs must have an executable format prepared by the NORD-50 loader. (:NOR5)
- starting the programs.
- reporting errors during program execution.
- examining the NORD-50 registers / memory after the programs have come to a stop (normal or abnormal stop).
Commands
The '*' is written by the monitor.[2]
- *PLACE <file name or number>
- load a program
- *RUN
- Start execution of the placed program
- *LOAD <file name or number>
- Load and start execution of a program, in effect PLACE and RUN
- *GO TO <address>
- start in given address