ND-100 Bus: Difference between revisions
(created the page) |
(added Logical layout section) |
||
(One intermediate revision by the same user not shown) | |||
Line 4: | Line 4: | ||
==Signals== | ==Signals== | ||
Each [[NORD-100]] bus backplane position contains a total of 96 lines (power and ground lines included). | Each [[NORD-100]] bus backplane position contains a total of 96 lines (power and ground lines included). | ||
==Logical layout== | |||
The [[ND-100]] bus may be divided into two logical parts | |||
*24-bit wide parallel multiplexed address / data lines | |||
*control lines | |||
The paired interrupt control lines (negative logic) INCONTR - OUTCONTR, INGRANT - OUTGRANT, INIDENT - OUTIDENT are connected OUTxxxx to INxxxx (daisy chain). The card position code lines PA0 - PA3 are connected to +5V and 0V like this: | |||
*PA0:0, PA1:0, PA2:0, PA3:0 - card position: rightmost (furthest from the CPU) | |||
*PA0:0, PA1:0, PA2:0, PA3:1 - card position: rightmost - 1 | |||
*PA0:0, PA1:0, PA2:1, PA3:0 - card position: rightmost - 2 | |||
* : | |||
in a binary sequence. | |||
The PA0 - PA3 signal lines were previously used by memory cards, but are now no longer used. | |||
All other signal and power lines are independent of card position. | |||
==Expansion== | ==Expansion== | ||
[[NORD-100]] card crates can be linked together via bus expander (BEX) modules. The number of crates to be lined together is set to a theoretical maximum of 8 crates. | [[NORD-100]] card crates can be linked together via bus expander (BEX) modules. The number of crates to be lined together is set to a theoretical maximum of 8 crates. | ||
== | ==References== | ||
{{ND-doc|06.016.01}} | *{{ND-doc|06.016.01}} | ||
*{{ND-doc|06.017.02}} | |||
*{{ND-doc|06.026.1}}, Chapter 4 | |||
[[Category:ND-100 hardware]] | [[Category:ND-100 hardware]] |
Latest revision as of 21:54, 20 December 2011
In the NORD-100 computer system all hardware modules are connected together via a common bus, the NORD-100 bus. All communication between NORD-100 modules is provided by this bus, except CPU, MMS and Cache communication. Therefore, the NORD-100 bus is general purpose, to allow all classes of NORD-100 modules simply to be "plugged" into the system.
Physical arrangement
The NORD-100 bus is available as a printed (card) backplane. The backplane is available in two versions containing either 12 or 21 positions for module connections. The two versions are otherwise equal.
Signals
Each NORD-100 bus backplane position contains a total of 96 lines (power and ground lines included).
Logical layout
The ND-100 bus may be divided into two logical parts
- 24-bit wide parallel multiplexed address / data lines
- control lines
The paired interrupt control lines (negative logic) INCONTR - OUTCONTR, INGRANT - OUTGRANT, INIDENT - OUTIDENT are connected OUTxxxx to INxxxx (daisy chain). The card position code lines PA0 - PA3 are connected to +5V and 0V like this:
- PA0:0, PA1:0, PA2:0, PA3:0 - card position: rightmost (furthest from the CPU)
- PA0:0, PA1:0, PA2:0, PA3:1 - card position: rightmost - 1
- PA0:0, PA1:0, PA2:1, PA3:0 - card position: rightmost - 2
- :
in a binary sequence.
The PA0 - PA3 signal lines were previously used by memory cards, but are now no longer used.
All other signal and power lines are independent of card position.
Expansion
NORD-100 card crates can be linked together via bus expander (BEX) modules. The number of crates to be lined together is set to a theoretical maximum of 8 crates.
References
- Norsk Data Document ND–06.016.01 ND-100 INPUT/OUTPUT SYSTEM
- Norsk Data Document ND–06.017.02 ND-100 BACKPLANE
- Norsk Data Document ND–06.026.1 ND-110 Functional Description , Chapter 4