3015: Difference between revisions
(created the page) |
m (added reference to 12.018.1) |
||
(6 intermediate revisions by 2 users not shown) | |||
Line 3: | Line 3: | ||
{{Stub}} | {{Stub}} | ||
==Introduction== | ==Introduction== | ||
HDLC Controller | |||
===CHARACTERISTICS=== | |||
Single-line serial interface for ND-100/110. | |||
Synchronous transmission format. | |||
HDLC (High-level Data Link Control) frame format handled in hardware. | |||
Direct Memory Access (DMA) transfer of data. | |||
Switch-selectable line connection: | |||
* V.24/V.28 for synchronous modem connection. | |||
* X.21/X.27 for X-DCE (datanet) connection. | |||
* Special computer link connection. | |||
* V.36/V.11 for 64 Kbit/s communication. | |||
* Optional V.35 for wideband modem connection. | |||
* Speed up to 307 kbps in computer link configuration. | |||
===APPLICATIONS=== | |||
COSMOS network. | |||
NORD-NET via synchronous modem or computer link. | |||
Datanet (X.21/X.25) connection. | |||
===TEST PROGRAMS=== | |||
NORD-CONFIGURATION-INVESTIGATOR: Tests device number and identcode. | |||
HDLC/MEGALINK: Tests the HDLC interface both off-line and on-line (see Testprogram Guide). | |||
XMSG-HDLC-TEST: Tests the HDLC interface on-line. | |||
==Switches and indicators== | ==Switches and indicators== | ||
The card has three thumbwheel switches numbered 3,2,1 from the top of the card. In addition it has switches at positions 13A, 17G and 26G. | The card has three thumbwheel switches numbered 3,2,1 from the top of the card. In addition it has switches at positions 13A, 17G and 26G. | ||
Line 27: | Line 61: | ||
positions 8 - 15 is not allowed. | positions 8 - 15 is not allowed. | ||
*Thumbwheel 3 - HDLC device number | *Thumbwheel 3 - HDLC device number | ||
**0 - HDLC 1 - device 1640 - ident | **0 - HDLC 1 - device 1640 - ident 150 | ||
**1 - HDLC 2 - device 1660 - ident 151 | **1 - HDLC 2 - device 1660 - ident 151 | ||
**2 - HDLC 3 - device 1700 - ident 152 | **2 - HDLC 3 - device 1700 - ident 152 | ||
Line 53: | Line 87: | ||
**xx0x - disable Abaud rate osc. | **xx0x - disable Abaud rate osc. | ||
**x0xx - disable main clock | **x0xx - disable main clock | ||
==Connectors== | ==Connectors== | ||
The A and B connectors are used for I/O, the C connector is used for the [[ND-100 Bus]]. | The A and B connectors are used for I/O, the C connector is used for the [[ND-100 Bus]]. | ||
==I/O Devices on the card== | ==I/O Devices on the card== | ||
none? | none? | ||
== ECO == | |||
ECO or Engineering Change Order is a hardware change. Here is a list of known ECO's for this card. | |||
* ECO 100-753E - System corruption if many DMA-controllers and ND-110 (3095 print) or ND-120 as CPU<ref name="ECO">sintran.com, Norsk Data library, ECO [http://sintran.com/sintran/library/libeco/libeco.html]</ref> | |||
==Reference== | ==Reference== | ||
{{ND-doc|06.015.02}} | *{{ND-doc|06.015.02}} | ||
*{{ND-doc|30.008.3 EN}} | |||
*{{ND-doc|12.018.1 EN}} | |||
[[Category:ND-100 hardware]] | [[Category:ND-100 hardware]] |
Latest revision as of 09:14, 22 October 2024
3015 is a HDLC + autoload controller.
This article is a stub. You can improve NDWiki by expanding it. |
Introduction
HDLC Controller
CHARACTERISTICS
Single-line serial interface for ND-100/110.
Synchronous transmission format.
HDLC (High-level Data Link Control) frame format handled in hardware.
Direct Memory Access (DMA) transfer of data.
Switch-selectable line connection:
- V.24/V.28 for synchronous modem connection.
- X.21/X.27 for X-DCE (datanet) connection.
- Special computer link connection.
- V.36/V.11 for 64 Kbit/s communication.
- Optional V.35 for wideband modem connection.
- Speed up to 307 kbps in computer link configuration.
APPLICATIONS
COSMOS network.
NORD-NET via synchronous modem or computer link.
Datanet (X.21/X.25) connection.
TEST PROGRAMS
NORD-CONFIGURATION-INVESTIGATOR: Tests device number and identcode.
HDLC/MEGALINK: Tests the HDLC interface both off-line and on-line (see Testprogram Guide).
XMSG-HDLC-TEST: Tests the HDLC interface on-line.
Switches and indicators
The card has three thumbwheel switches numbered 3,2,1 from the top of the card. In addition it has switches at positions 13A, 17G and 26G.
- Thumbwheel 1 - baud rate
- 0 - 307 K baud
- 3 - 1.2 K baud
- 6 - 9.6 K baud
- 7 - 38.4 K baud
- 8 - 153.6 K baud
- 9 - 76.8 K baud
- 11 - 19.2 K baud
- 13 - 4.8 K baud
- 14 - 2.4 K baud
- Thumbwheel 2 - autoload device number
- 0 - device 1600 - not allowed
- 1 - device 1604
- 2 - device 1610
- 3 - device 1614
- 4 - device 1620
- 5 - device 1624
- 6 - device 1630
- 7 - device 1634
positions 8 - 15 is not allowed.
- Thumbwheel 3 - HDLC device number
- 0 - HDLC 1 - device 1640 - ident 150
- 1 - HDLC 2 - device 1660 - ident 151
- 2 - HDLC 3 - device 1700 - ident 152
- 3 - HDLC 4 - device 1720 - ident 153
- 4 - HDLC 5 - device 1740 - ident 154
- 5 - HDLC 6 - device 1760 - ident 155
- 6 - HASP 1 - device 560 - ident 156
- 7 - HASP 2 - device 620 - ident 157
- 9 - HASP 3 - device 700 - ident 160
- 9 - HASP 4 - device 720 - ident 161
- 10 - HASP 5 - device 1500 - ident 162
- 11 - HASP 6 - device 1520 - ident 163
Switches are read 4321, switch on = 1, switch off = 0
- 13A switch -
- xx00 - X.21
- xx01 - Computer link
- xx10 - V.35
- xx11 - V.24 / X.21 bis
- 17G switch -
- 26G switch -
- xx0x - disable Abaud rate osc.
- x0xx - disable main clock
Connectors
The A and B connectors are used for I/O, the C connector is used for the ND-100 Bus.
I/O Devices on the card
none?
ECO
ECO or Engineering Change Order is a hardware change. Here is a list of known ECO's for this card.
- ECO 100-753E - System corruption if many DMA-controllers and ND-110 (3095 print) or ND-120 as CPU[1]
Reference
- Norsk Data Document ND–06.015.02 ND-100 FUNCTIONAL DESCRIPTION
- Norsk Data Document ND–30.008.3 EN ND-100 Hardware Maintenance
- Norsk Data Document ND–12.018.1 EN HDLC INTERFACE