(created 3026 page) |
(→ECO: add 100-755) |
||
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
'''3026''' is a [[GPIB]] controller. | '''3026''' is a [[GPIB]]<ref>[[Wikipedia:GPIB]]</ref> controller. | ||
{{Stub}} | {{Stub}} | ||
==Introduction== | ==Introduction== | ||
Line 29: | Line 29: | ||
==I/O Devices on the card== | ==I/O Devices on the card== | ||
none? | none? | ||
== ECO == | |||
Here is a list of known ECO's (Engineering Change Order) for this card. | |||
* ECO 100-755 - Only valid with remote-box. May loose data. Status: REMOTE BOX NOT CONNECTED.<ref name="ECO"></ref> | |||
* ECO 100-784 - May give various errors as ERROR 70, 72, 73<ref name="ECO">sintran.com, Norsk Data library, ECO [http://sintran.com/sintran/library/libeco/libeco.html]</ref> | |||
==References== | ==References== | ||
*{{ND-doc|30.008.3 EN}}, page 198 | *{{ND-doc|30.008.3 EN}}, page 198 | ||
<references/> | |||
[[Category:ND-100 hardware]] | [[Category:ND-100 hardware]] |
Latest revision as of 17:10, 3 April 2023
This article is a stub. You can improve NDWiki by expanding it. |
Introduction
What does it do?
Switches and indicators
- Thumbwheel 1 - device-number switch
- 1: device 0, dev.no (octal) 140000, Ident code (octal) 140000
- 2: device 1, dev.no (octal) 140010, Ident code (octal) 140001
- 3: device 0, dev.no (octal) 141400, Ident code (octal) 140140
- 4: device 0, dev.no (octal) 141410, Ident code (octal) 140141
- 5: device 0, dev.no (octal) 141420, Ident code (octal) 140142
- 6: device 0, dev.no (octal) 141430, Ident code (octal) 140143
- 7: device 0, dev.no (octal) 141440, Ident code (octal) 140144
- 8: device 0, dev.no (octal) 141450, Ident code (octal) 140145
- LED 6 (yellow) : SYC - system-controller switch in ON position
- LED 5 (yellow) : REMOK - REMote OK, remote option in fumction
- LED 4 (yellow) : DMACT - DMA ACTive
- LED 3 (red) : ERROR - Z80 microprogram has detected an error
- LED 2 (green) : FIFO - First-In-First-Out register is empty
- LED 1 (green) : RFT - Ready for transfer
- System-controller switch
- switch ON: ND-100 is system controller
- switch OFF: ND-100 is NOT system controller
Connectors
The A and B connectors are used for I/O, the C connector is used for the ND-100 Bus.
I/O Devices on the card
none?
ECO
Here is a list of known ECO's (Engineering Change Order) for this card.
- ECO 100-755 - Only valid with remote-box. May loose data. Status: REMOTE BOX NOT CONNECTED.[2]
- ECO 100-784 - May give various errors as ERROR 70, 72, 73[2]
References
- Norsk Data Document ND–30.008.3 EN ND-100 Hardware Maintenance , page 198
- ↑ Wikipedia:GPIB