3026: Difference between revisions

From NDWiki
Jump to navigation Jump to search
(created 3026 page)
 
(→‎ECO: add 100-755)
 
(2 intermediate revisions by the same user not shown)
Line 1: Line 1:
'''3026''' is a [[GPIB]] controller.
'''3026''' is a [[GPIB]]<ref>[[Wikipedia:GPIB]]</ref> controller.
{{Stub}}
{{Stub}}
==Introduction==
==Introduction==
Line 29: Line 29:
==I/O Devices on the card==
==I/O Devices on the card==
none?
none?
== ECO ==
Here is a list of known ECO's (Engineering Change Order) for this card.
* ECO 100-755 - Only valid with remote-box. May loose data. Status: REMOTE BOX NOT CONNECTED.<ref name="ECO"></ref>
* ECO 100-784 - May give various errors as ERROR 70, 72, 73<ref name="ECO">sintran.com, Norsk Data library, ECO [http://sintran.com/sintran/library/libeco/libeco.html]</ref>


==References==
==References==
*{{ND-doc|30.008.3 EN}}, page 198
*{{ND-doc|30.008.3 EN}}, page 198
<references/>


[[Category:ND-100 hardware]]
[[Category:ND-100 hardware]]

Latest revision as of 17:10, 3 April 2023

3026 is a GPIB[1] controller.

Introduction

What does it do?

Switches and indicators

  • Thumbwheel 1 - device-number switch
    • 1: device 0, dev.no (octal) 140000, Ident code (octal) 140000
    • 2: device 1, dev.no (octal) 140010, Ident code (octal) 140001
    • 3: device 0, dev.no (octal) 141400, Ident code (octal) 140140
    • 4: device 0, dev.no (octal) 141410, Ident code (octal) 140141
    • 5: device 0, dev.no (octal) 141420, Ident code (octal) 140142
    • 6: device 0, dev.no (octal) 141430, Ident code (octal) 140143
    • 7: device 0, dev.no (octal) 141440, Ident code (octal) 140144
    • 8: device 0, dev.no (octal) 141450, Ident code (octal) 140145
  • LED 6 (yellow) : SYC - system-controller switch in ON position
  • LED 5 (yellow) : REMOK - REMote OK, remote option in fumction
  • LED 4 (yellow) : DMACT - DMA ACTive
  • LED 3 (red)  : ERROR - Z80 microprogram has detected an error
  • LED 2 (green)  : FIFO - First-In-First-Out register is empty
  • LED 1 (green)  : RFT - Ready for transfer
  • System-controller switch
    • switch ON: ND-100 is system controller
    • switch OFF: ND-100 is NOT system controller

Connectors

The A and B connectors are used for I/O, the C connector is used for the ND-100 Bus.

I/O Devices on the card

none?

ECO

Here is a list of known ECO's (Engineering Change Order) for this card.

  • ECO 100-755 - Only valid with remote-box. May loose data. Status: REMOTE BOX NOT CONNECTED.[2]
  • ECO 100-784 - May give various errors as ERROR 70, 72, 73[2]

References

  1. Wikipedia:GPIB
  2. 2.0 2.1 sintran.com, Norsk Data library, ECO [1]