3033: Difference between revisions
Jump to navigation
Jump to search
(created the page) |
(→Connectors: detailed B connector usage.) |
||
Line 28: | Line 28: | ||
Setting 14 and 15 is not defined (not used?). | Setting 14 and 15 is not defined (not used?). | ||
==Connectors== | ==Connectors== | ||
General: the A and B connectors are used for I/O, the C connector is used for the [[ND-100 Bus]]. | |||
On this CPU module, the B connector connects to the memory management module in slot 2. | |||
==I/O Devices on the card== | ==I/O Devices on the card== | ||
==Reference== | ==Reference== | ||
{{ND-doc|06.015 (ND-06.015.02)}} | {{ND-doc|06.015 (ND-06.015.02)}} |
Revision as of 23:51, 4 December 2011
3033 is the ND-100 CPU with CX option board. It contains the CPU, bus arbitration logic, memory control and other subsystems. It also has the Real time clock and the I/O for the serial console.
This article is a stub. You can improve NDWiki by expanding it. |
Introduction
Switches and indicators
As seen from the top, when the card is in the card crate (components on the right hand side).
console speed thumbwheel switch ALD thumbwheel switch green LED - cpu self test ok red LED - cpu self test not ok
Console speed setting
- 0 - 110 baud
- 1 - 150 baud
- 2 - 300 baud
- 3 - 2400 baud
- 4 - 1200 baud
- 5 - 1800 baud
- 6 - 4800 baud
- 7 - 9600 baud
- 8 - 2400 baud
- 9 - 600 baud
- 10 - 200 baud
- 11 - 134.5 baud
- 12 - 75 baud
- 13 - 50 baud
Setting 14 and 15 is not defined (not used?).
Connectors
General: the A and B connectors are used for I/O, the C connector is used for the ND-100 Bus. On this CPU module, the B connector connects to the memory management module in slot 2.
I/O Devices on the card
Reference
Norsk Data Document ND–06.015 (ND-06.015.02) ND-100 FUNCTIONAL DESCRIPTION