3015: Difference between revisions

From NDWiki
Jump to navigation Jump to search
(Added content to "Introduction")
Line 3: Line 3:
{{Stub}}
{{Stub}}
==Introduction==
==Introduction==
HDLC Controller


Special intercomputer link interface for highspeed communication between ND-110/ND-110 or ND-110/N-10/10-S (see ND-726)
===CHARACTERISTICS===


A MEGALINK interface can only communicate with another MEGALINK interface.
Single-line serial interface for ND-100/110.


Synchronous transmission format.
Synchronous transmission format.


HDLC (High level Data Link Control) frame format handled in hardware.
HDLC (High-level Data Link Control) frame format handled in hardware.


Direct Memory Access (DMA) transfer of data.
Direct Memory Access (DMA) transfer of data.


Line connection: Special computerlink connection with balanced drivers/receivers (RS-422).
Switch-selectable line connection:
* V.24/V.28 for synchronous modem connection.
* X.21/X.27 for X-DCE (datanet) connection.
* Special computer link connection.
* V.36/V.11 for 64 Kbit/s communication.
* Optional V.35 for wideband modem connection.
* Speed up to 307 kbps in computer link configuration.
===APPLICATIONS===


Speed up to 983kbps.
COSMOS network.


  For machine-to-machine cable, check out cable 325402 in Service Handbook II, chapter 2-20 - http://norsk-data.com/library/libsw/ND-NDSH02-03-EN.pdf (http://norsk-data.com/library/libsw/libsw.html)
NORD-NET via synchronous modem or computer link.
 
Datanet (X.21/X.25) connection.


==Switches and indicators==
==Switches and indicators==

Revision as of 14:21, 11 October 2024

3015 is a HDLC + autoload controller.

Introduction

HDLC Controller

CHARACTERISTICS

Single-line serial interface for ND-100/110.

Synchronous transmission format.

HDLC (High-level Data Link Control) frame format handled in hardware.

Direct Memory Access (DMA) transfer of data.

Switch-selectable line connection:

  • V.24/V.28 for synchronous modem connection.
  • X.21/X.27 for X-DCE (datanet) connection.
  • Special computer link connection.
  • V.36/V.11 for 64 Kbit/s communication.
  • Optional V.35 for wideband modem connection.
  • Speed up to 307 kbps in computer link configuration.

APPLICATIONS

COSMOS network.

NORD-NET via synchronous modem or computer link.

Datanet (X.21/X.25) connection.

Switches and indicators

The card has three thumbwheel switches numbered 3,2,1 from the top of the card. In addition it has switches at positions 13A, 17G and 26G.

  • Thumbwheel 1 - baud rate
    • 0 - 307 K baud
    • 3 - 1.2 K baud
    • 6 - 9.6 K baud
    • 7 - 38.4 K baud
    • 8 - 153.6 K baud
    • 9 - 76.8 K baud
    • 11 - 19.2 K baud
    • 13 - 4.8 K baud
    • 14 - 2.4 K baud
  • Thumbwheel 2 - autoload device number
    • 0 - device 1600 - not allowed
    • 1 - device 1604
    • 2 - device 1610
    • 3 - device 1614
    • 4 - device 1620
    • 5 - device 1624
    • 6 - device 1630
    • 7 - device 1634

positions 8 - 15 is not allowed.

  • Thumbwheel 3 - HDLC device number
    • 0 - HDLC 1 - device 1640 - ident 150
    • 1 - HDLC 2 - device 1660 - ident 151
    • 2 - HDLC 3 - device 1700 - ident 152
    • 3 - HDLC 4 - device 1720 - ident 153
    • 4 - HDLC 5 - device 1740 - ident 154
    • 5 - HDLC 6 - device 1760 - ident 155
    • 6 - HASP 1 - device 560 - ident 156
    • 7 - HASP 2 - device 620 - ident 157
    • 9 - HASP 3 - device 700 - ident 160
    • 9 - HASP 4 - device 720 - ident 161
    • 10 - HASP 5 - device 1500 - ident 162
    • 11 - HASP 6 - device 1520 - ident 163

Switches are read 4321, switch on = 1, switch off = 0

  • 13A switch -
    • xx00 - X.21
    • xx01 - Computer link
    • xx10 - V.35
    • xx11 - V.24 / X.21 bis
  • 17G switch -
    • ---0 - disable MCL
    • --0- - disable LOAD
    • -0-- - disable RML
    • 0--- - disable CLOAD
  • 26G switch -
    • xx0x - disable Abaud rate osc.
    • x0xx - disable main clock

Connectors

The A and B connectors are used for I/O, the C connector is used for the ND-100 Bus.

I/O Devices on the card

none?

ECO

ECO or Engineering Change Order is a hardware change. Here is a list of known ECO's for this card.

  • ECO 100-753E - System corruption if many DMA-controllers and ND-110 (3095 print) or ND-120 as CPU[1]

Reference

  1. sintran.com, Norsk Data library, ECO [1]